TS 600

GENERAL FEATURES

In the following sections you can see the entire tables by scrolling them to the right and to the left

POS. DESCRIPTION MATERIALS SPARES
1 Body ASTM A234 WPB ASTM A420 WPL6 ASTM WP 403 F316 ASTM A234 WP5
1.2 Flange ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5
1.3 Guide rods S.S. 304 S.S. 304 S.S. 304 S.S. 304
2 Blind flange ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5
3 *Basket S.S. 304 S.S. 304 S.S. 304 S.S. 304 X
4 Gasket SS316/Graph. SS316/Graph. SS316/Graph. SS316/Graph. X
5 Stud Bolts ASTM A193 B7 ASTM A320 L7 ASTM A320 L7 ASTM A193 B7
6 Nuts ASTM A194 2H ASTM A194 Gr.4 ASTM A194 Gr.4 ASTM A194 2H
7 Plug ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

OTHER MATERIALS AND DIMENSIONS ON REQUEST

* BASKET TYPE: V - W - WW - Z. Basket configuration depend of % ratio requested by customer

CONNECTIONS

Buttweld ANSI B16.25

Flanged ANSI B16.5

STRAINER DESCRIPTION

Designed according to ANSI B16.34 the strainer bodies are produced with a superior wallthickness for corrosion allowance. Standard stainers are equipped with screens for the average service of most mediums ( steam, gas, air, oil, chemicals , ect. ). The large screen open area ensures an efficent filtering action with a low pressure drop. Filtering area to inlet area ratio is larger than 3 to 1 . Screens area manufactured with perforated plate in the materials and with the perforation specified in the relevant tables . Screens with different perforation ( or wire mesh ) and materials may be manufactured on request.

SIZES / DIMENSIONS

Size (inches) 2” 3” 4” 6” 8” 10”
S 127 172 210 286 356432
S (RF) 286 351 427 535 636750
H 177 216 260 324 382447

Size (inches) 12” 16” 18” 20” 24”
S 508 610 686 762 864
S(RF) 833 979 1067 1156 1284
H 492 574 624 676 753
Dimension : SF , S , H are in millimeters ( mm)

HOW TO SERVICE

Strainer maintenace should be made at least once year, or whenever the pressure drop is found to be in excess of the normal figures. A quick clean-up system, to made approximately once a mounth. For a complete maintenance follow the points herebelow:


  1. Be sure that the main line has been shut-off
  2. Untighten cover stud bolts (5) and nuts (6) and remove cover [ blind flange ] (2) and gasket (4)
  3. Withdraw basket (3) an carefully inspect it for damages. If any hole in the screen is found abstructed, clean it with compressed air and / or any suitable tool. If the basket is broken in any part or out of shape, replace it with a new spare one.
  4. Carefully clean the inside of the strainer body
  5. Fit a new gasket (4)
  6. Install the new screen or the cleaned one (3)
  7. Put in place cover (2)
  8. Slowly give pressure to the line, checking for leakages
  9. Write on the strainer body the date of this maintenance operation